iMAX B6 notes: modes, settings, and pre-charge checks
The iMAX B6 supports several battery chemistries, but an incorrect chemistry, cell count, or charging setting can be dangerous. These notes reorganize the older material around the operating sequence. Use the manual for your exact charger revision and the battery manufacturer's specifications for actual operation.
Identify the model and power supply
Do not interchange specifications for the original iMAX B6, B6AC, B6 Mini, or other models. SkyRC lists these specifications for the original B6:
| Item | Original iMAX B6 |
|---|---|
| Input | 11–18 V DC |
| Maximum charge / discharge power | 50 W / 5 W |
| Charge / discharge current range | 0.1–5.0 A / 0.1–1.0 A |
| Balancing current | 300 mA per cell |
| Supported cell counts | 1–15 NiCd/NiMH cells; 1–6 lithium cells |
This B6 cannot be connected directly to mains electricity. The old notes mixed an AC input specification into the same table, inviting confusion with the B6AC. Check the model, input label, supply voltage, and polarity. Appearance or the supply's current rating alone does not establish compatibility. The maximum current is also subject to the charger's power limit. Model and specification source.
Checks before connecting a battery
Identify the chemistry, series cell count, capacity, and permitted charge/discharge conditions. Do not try to “revive” swollen, damaged, leaking, or unidentified batteries. Supervise charging on a ventilated, heat-resistant, nonflammable surface away from combustible materials.
Following the manual, connect the charging lead to the charger before connecting the battery, so exposed battery-connected plugs cannot short together. After stopping the output, disconnect the battery before removing the leads. Balance charging requires both the main power lead and the correct balance connector. Match connector orientation, cell count, and any adapter board. See the manufacturer's wiring and safety instructions.
Buttons and operating modes
| Button | Main purpose |
|---|---|
Batt. Type / Stop |
Select a battery type or go back; stop a running process |
Dec. / Inc. |
Change values or inspect status items |
Start / Enter |
Enter or confirm settings; start as instructed by the firmware |
Select the chemistry before the mode. LiPo, LiIo, and LiFe are not interchangeable. A battery's nominal voltage is not an arbitrary charge-termination setting.
| Mode | Meaning and considerations |
|---|---|
CHARGE |
Ordinary charging; does not imply the individual-cell balancing performed in BALANCE mode |
BALANCE |
Balance charging for compatible multi-cell lithium packs; both connections are required |
STORAGE |
Adjusts a compatible pack for storage by charging or discharging; there is no need to charge it fully beforehand |
DISCHARGE |
Controlled discharge; use battery-specific termination conditions, not a universal cutoff |
FAST CHG |
A different process from ordinary or balance charging; consult the matching manual first |
CYCLE |
Alternating charge/discharge in the appropriate NiMH/NiCd program; not a repair method for damaged lithium batteries |
Set current and verify cell count
Use the battery manufacturer's permitted charging current. Neither 1C nor a lower rate is a universal default. For example, 1C corresponds to 2.2 A for a 2200 mAh pack; this is a unit conversion, not a charging recommendation.
Older screens show R and S before starting: the detected and manually selected series cell counts. Both must agree with each other and with the battery label. Detection does not replace checking. If they differ, stop and inspect the chemistry, connections, and battery condition rather than changing a number just to continue.
The running screen usually shows current, voltage, elapsed time, and accumulated capacity. That capacity is a measurement from the current process, not a complete battery-health assessment. Stop if the charger reports an error such as CONNECTION BREAK, or if there is abnormal heat or deformation, and follow the equipment instructions.
NiMH, NiCd, and lead-acid batteries
NiMH/NiCd programs use different termination criteria from lithium programs. In older menus, CHARGE Man uses the selected current; CUR LIMIT in automatic mode sets a current ceiling. Automatic operation does not remove the need to identify the battery correctly.
Choose cycle counts, rest periods, discharge termination conditions, and lead-acid voltage settings from the relevant battery documentation. Do not transfer lithium storage or balancing settings to other chemistries, or use nickel-battery cycling to “activate” a lithium pack.
Protection settings and saved presets
Safety Timer, Capacity Cut-Off, and temperature protection are additional safeguards. Do not simply disable them to make a process continue. Set limits according to the battery requirements, charging current, and expected duration. Temperature protection also requires a correctly fitted compatible probe; without it, that protection cannot be relied upon.
SAVE DATA / LOAD DATA simplify repeated setup, but recheck loaded settings against the connected battery. Adjust sounds only while retaining a way to notice completion and faults. A stopped process does not necessarily mean a full battery: check why it stopped.